Installer ManualZeus Multi-function DisplayEnglish
Overview | 91 2 5 634Key Description1Power. For power input 12 or 24 V DC input (see power section), Power control (see Power Control section) and e
10 | Installing the Display Installing the Display 5. Mounting locationChoose the mounting locations carefully before you drill or cut. The display sh
Installing the Display | 11Cut out shaded areaPanel Mount212 mm (8.34”)285 mm (11.20)265 mm (10.40”) CLEARANCE HOLE TO SUIT M4 MACHINE SCREW
12 | Installing the Display Bracket MountAn alternative to flush mounting the Z8 or Z12 is to bracket mount the unit. This method has the advantage th
Installing the Display | 13Drill a pilot hole for the fi ve screws 5 and an optional hole large enough for the cables to emerge from.Secure 5 the br
14 | System Architecture System Architecture 6. This section explains how the Zeus connects to other devices as part of a system. The Zeus has a highl
System Architecture | 15Data BridgingSupported NMEA0183 sentences entering the system are bridged (converted) to •SimNet/NMEA2000 and distributed o
16 | Wiring Information 7 way joinerZeus Z12Gimballed Rate CompassH3000CPUGFD Displays20/20HVDisplaysMastheadUnitSpeed & DepthSensorsAISNAIS-300GP
Wiring Information | 17Standard ConnectionsNMEA0183 DevicesVideo / Comms - NMEA0183NMEA0183 DeviceZeus DisplayH3000Zeus Display H3000H-Link (USB)Dec
18 | Wiring Information WTP3Zeus DisplaySerial InterfaceVideo / Comms - NMEA0183DeckmanNavigation SoftwareWTP3CanNetworkEthernet
Preface | 1Preface 1. DisclaimerAs Navico is continuously improving this product, we retain the right to make changes to the product at any time whi
Wiring the Zeus Display | 19Wiring the Zeus Display 8. Wiring guidelinesMost installation problems are caused by shortcuts taken with system cables.
20 | Wiring the Zeus Display PowerThe Zeus displays can be powered by either 12 V or 24 V DC. Displays are protected against reverse polarity, under
Wiring the Zeus Display | 2112 - 24 V DCRed (FUSE)BlackYellowNo Connect+_Blue12 - 24 V DCRed (FUSE)BlackYellowBlue+_No Power ControlDisplay will tur
22 | Wiring the Zeus Display Power Control Table Slave MasterCan turn on by own PWR button YES * YESCan turn off by own PWR button YES * YESCan turn o
Wiring the Zeus Display | 23 External AlarmAn external alarm can be connected to one or more displays on the network. The external alarm can be a sm
24 | Wiring the Zeus Display H-LinkH-Link is B&G’s protocol for comprehensive and efficient interfacing of the B&G H3000 processor range used
Wiring the Zeus Display | 25 SimNetSimNet is a data network based on NMEA2000 CAN bus technology that makes interconnection and integration of B&
26 | Wiring the Zeus Display NMEA2000 devices can be connected to the SimNet Network providing they: •are NMEA2000 certified -meet the CE, FCC regulat
Wiring the Zeus Display | 2712 V DCABC D EFT TTSimNet drop cableSimNet powerSimNet terminator-+A slightly larger system below. Power is connected at
28 | Wiring the Zeus Display Ethernet The Zeus system uses an Ethernet network to interconnect high bandwidth devices such as other Zeus displays, ra
2 | Preface Declaration of ConformityGBHereby, Navico Holding AS declares that this Z8, Z12 is in compliance with the essential requirements and other
Wiring the Zeus Display | 29 Dual and Multi StationIf there is more than one display it is recommended to use a network expansion portPOWERNETWORKNE
30 | Wiring the Zeus Display NMEA0183 WiringTo exchange NMEA0183 data, the Zeus display units have a NMEA0183 communication port. The port uses RS422
Wiring the Zeus Display | 31 Video InConnect up to two composite video cameras to each display unit using the supplied Video / Data cable. This conn
32 | Wiring the Zeus Display Video OutThe Zeus display has a DVI-I Video connector. Connect a second display to replicate what is on the screen of th
Wiring the Zeus Display | 33Connecting BroadBand™ Radar+_BCDEFFGGIJHHAPowerScanner cableSimNetNetworkBrown RX-White RX+AT10HDNMEA0183 to SimNetConve
34 | Wiring the Zeus Display Connecting HD Radar2 kW 12 V DC ONLY4 kW & 6 kW 12 or 24 V DC10 kW & 25 kW 24 V DC ONLY+_BCDDEFKKGIJHHAEthernetSc
Wiring the Zeus Display | 35Connecting BSM1 Broadband Echosounder+_ABBCDEF1234576Key DescriptionA Zeus DisplayB BSM-1 Broadband Echosounder moduleCE
36 | Commission the System Commission the System 9. Turning on the system for the fi rst timeBefore starting the system for the first time, check the f
Commission the System | 37Commissioning ChecklistThe Zeus has a number of advanced features which can be configured through the settings menu.It is
38 | Commission the System System settings menuTo access the system settings menu press LanguageLanguage used on menus and dialog boxesStep 1 Step 2 S
Preface | 3Contents 2. Preface ... 1Introduction ...
Commission the System | 39Echosounder Setup Depth OffsetIs a value that can be entered to make the depth on the Echo page represent either depth bel
40 | Commission the System Water Speed AveragingAverages water speed by measuring your speed at a selected interval of time. Water speed intervals ra
Commission the System | 41Radar Transmit, Standby or offPress Radar function button to display the radarMENU9WINPress Menu to bring up radar options
42 | Commission the System Data SetupData set up is required on initial start up of the system, or if any part of the SimNet or NMEA 2000 network has
Commission the System | 43each of these categories a display can be set to receive data from sources as part of the Default group or receive the sou
44 | Commission the System SimNet GroupsThe SimNet Group function is used to control parameter settings, either globally or in groups of units. It gr
Commission the System | 45DampingControls how quickly instruments respond to changes in values from sensors. Damping can be used for heading, wind,
46 | Commission the System Serial Port SetupConfigure the serial port to match the NMEA0183 device that it is connected to.Baud Rate (common for inpu
Commission the System | 47FuelIf the vessel has an NMEA2000 interface to its engines and fuel tanks. Zeus can display the following fuel consumption
48 | Commission the System DiagnosticsNMEA2000 DiagnosticsUser Database UDBThe diagnostic page shows the MAC address of the display, the status and ve
4 | Preface Ethernet ... 28Dual and Multi Station 29NMEA0183 Wirin
Commission the System | 49Check GPS SignalPress direct access key PAGES (3) If interfaced to H3000 Instruments via H-Link this feature is available
50 | Commission the System Restore a System Backup FileRestoring data from a backup file will overwrite all existing data and settings with the data a
Commission the System | 51Ethernet Module Software VersionSoftware version : CA1637CExample below shows upgrading a ZG50 GPS Antenna. Steps 1 - 3 ar
52 | Commission the System Screen CaptureIt is possible to capture a snap shot of the current screenStep 1 Step 2Enable screen captureCreate desired s
Drawings | 53Drawings 10. Z8 Dimensions111.3 mm (4.38”)86.5 mm (3.40”)285.0 mm (11.22”)221.0 mm (8.70”)212.0 mm (8.35”)315.5 mm (12.40”)35 mm (1.38”
54 | Drawings Z12 Dimensions357.0 mm (14.01”)385 mm (15.16”)273.0 mm (10.75”)266.0 mm (10.47”)122.7 mm (4.83”)98 mm (3.85”)65 mm (2.55”)35 mm (1.38”)
Spare Parts | 55Spare Parts 11. Zeus Spare PartsPart Number Description000-10406-001 Bezel,Zeus,Z8000-10405-001 Bezel,Zeus,Z12000-10408-001 Sun cove
56 | Spare Parts Compatible BSM-1 TransducersPart Number Description000-0136-02 Airmar P319, plastic, low profi le, thru hull 50/200 KHz, depth/temp,
Spare Parts | 5724005894 SimNet termination plug44172278 SimNet termination In-Line joiner24005902 2 m (6.6 ft) SimNet power w/termination24005910 2
58 | Specifi cations Specifi cations 12. MechanicalBack Case Die cast aluminium Heat Sinking Direct heat transfer from processor to castingScreen Direct
Preface | 5Drawings ... 53Z8 Dimensions ...
Specifi cations | 59Display Specifi c Specifi cationsZ8 Z12Display size 8 “ Diagonal Display size 12.1” DiagonalDisplay resolution 800 x 600 Display re
60 | Specifi cations NMEA 2000 PGN ListNMEA 2000 PGN Receive59392 ISO Acknowledgement59904 ISO Request60928 ISO Address Claim60928 ISO Address Claim1
Specifi cations | 61NMEA2000 PGN Transmit126208 ISO Command Group Function126992 System Time126996 Product Info127237 Heading/Track Control127250 Ve
www.bandg.com*988-0186-01A*
6 | Introduction Introduction 3. About this ManualThis manual is a reference guide for installing the B&G Z8 and Z12 Multi Function Display.The in
Introduction | 7Check the PartsPackaged Parts List8“ Display unitPN location specifi cZ8 Bezel000-10406-00112 “ Display unitPN location specifi cZ12 B
8 | Overview Overview 4. ECHORADARCHART NAV INFO PAGESMENUPLOTGO TOMARKVESSELWININMOBABC DEF123JKLGHI MNO456TUVPQRSWXYZ7STBYAUTOPWR809OUT12 4679115810