Installer Manual
Zeus Multi-function Display
English
Vista de página 0
1 2 3 4 5 6 ... 62 63

Resumo do Conteúdo

Página 1 - Installer Manual

Installer ManualZeus Multi-function DisplayEnglish

Página 2 - Preface 1

Overview | 91 2 5 634Key Description1Power. For power input 12 or 24 V DC input (see power section), Power control (see Power Control section) and e

Página 3 - Disposal

10 | Installing the Display Installing the Display 5. Mounting locationChoose the mounting locations carefully before you drill or cut. The display sh

Página 4 - Contents 2

Installing the Display | 11Cut out shaded areaPanel Mount212 mm (8.34”)285 mm (11.20)265 mm (10.40”) CLEARANCE HOLE TO SUIT M4 MACHINE SCREW

Página 5 - 4

12 | Installing the Display Bracket MountAn alternative to flush mounting the Z8 or Z12 is to bracket mount the unit. This method has the advantage th

Página 6 - Preface

Installing the Display | 13Drill a pilot hole for the fi ve screws 5 and an optional hole large enough for the cables to emerge from.Secure 5 the br

Página 7 - Introduction 3

14 | System Architecture System Architecture 6. This section explains how the Zeus connects to other devices as part of a system. The Zeus has a highl

Página 8 - Check the Parts

System Architecture | 15Data BridgingSupported NMEA0183 sentences entering the system are bridged (converted) to •SimNet/NMEA2000 and distributed o

Página 9 - Overview 4

16 | Wiring Information 7 way joinerZeus Z12Gimballed Rate CompassH3000CPUGFD Displays20/20HVDisplaysMastheadUnitSpeed & DepthSensorsAISNAIS-300GP

Página 10 - 1 2 5 63

Wiring Information | 17Standard ConnectionsNMEA0183 DevicesVideo / Comms - NMEA0183NMEA0183 DeviceZeus DisplayH3000Zeus Display H3000H-Link (USB)Dec

Página 11 - Installing the Display 5

18 | Wiring Information WTP3Zeus DisplaySerial InterfaceVideo / Comms - NMEA0183DeckmanNavigation SoftwareWTP3CanNetworkEthernet

Página 12 - Panel Mount

Preface | 1Preface 1. DisclaimerAs Navico is continuously improving this product, we retain the right to make changes to the product at any time whi

Página 13 - Bracket Mount

Wiring the Zeus Display | 19Wiring the Zeus Display 8. Wiring guidelinesMost installation problems are caused by shortcuts taken with system cables.

Página 14 - Installing the Display

20 | Wiring the Zeus Display PowerThe Zeus displays can be powered by either 12 V or 24 V DC. Displays are protected against reverse polarity, under

Página 15 - System Architecture 6

Wiring the Zeus Display | 2112 - 24 V DCRed (FUSE)BlackYellowNo Connect+_Blue12 - 24 V DCRed (FUSE)BlackYellowBlue+_No Power ControlDisplay will tur

Página 16 - DISPLAY 2

22 | Wiring the Zeus Display Power Control Table Slave MasterCan turn on by own PWR button YES * YESCan turn off by own PWR button YES * YESCan turn o

Página 17 - Wiring Information 7

Wiring the Zeus Display | 23 External AlarmAn external alarm can be connected to one or more displays on the network. The external alarm can be a sm

Página 18 - NMEA0183 Device

24 | Wiring the Zeus Display H-LinkH-Link is B&G’s protocol for comprehensive and efficient interfacing of the B&G H3000 processor range used

Página 19

Wiring the Zeus Display | 25 SimNetSimNet is a data network based on NMEA2000 CAN bus technology that makes interconnection and integration of B&

Página 20 - Wiring the Zeus Display 8

26 | Wiring the Zeus Display NMEA2000 devices can be connected to the SimNet Network providing they: •are NMEA2000 certified -meet the CE, FCC regulat

Página 21 - 2 m (6.5 ft)

Wiring the Zeus Display | 2712 V DCABC D EFT TTSimNet drop cableSimNet powerSimNet terminator-+A slightly larger system below. Power is connected at

Página 22 - BR24 Radar

28 | Wiring the Zeus Display Ethernet The Zeus system uses an Ethernet network to interconnect high bandwidth devices such as other Zeus displays, ra

Página 23 - 22

2 | Preface Declaration of ConformityGBHereby, Navico Holding AS declares that this Z8, Z12 is in compliance with the essential requirements and other

Página 24 - External Alarm

Wiring the Zeus Display | 29 Dual and Multi StationIf there is more than one display it is recommended to use a network expansion portPOWERNETWORKNE

Página 25 - B&G H-Link Pro

30 | Wiring the Zeus Display NMEA0183 WiringTo exchange NMEA0183 data, the Zeus display units have a NMEA0183 communication port. The port uses RS422

Página 26

Wiring the Zeus Display | 31 Video InConnect up to two composite video cameras to each display unit using the supplied Video / Data cable. This conn

Página 27 - Power the SimNet Network

32 | Wiring the Zeus Display Video OutThe Zeus display has a DVI-I Video connector. Connect a second display to replicate what is on the screen of th

Página 28 - SimNet drop cable

Wiring the Zeus Display | 33Connecting BroadBand™ Radar+_BCDEFFGGIJHHAPowerScanner cableSimNetNetworkBrown RX-White RX+AT10HDNMEA0183 to SimNetConve

Página 29 - Ethernet

34 | Wiring the Zeus Display Connecting HD Radar2 kW 12 V DC ONLY4 kW & 6 kW 12 or 24 V DC10 kW & 25 kW 24 V DC ONLY+_BCDDEFKKGIJHHAEthernetSc

Página 30 - DISPLAY A DISPLAY B

Wiring the Zeus Display | 35Connecting BSM1 Broadband Echosounder+_ABBCDEF1234576Key DescriptionA Zeus DisplayB BSM-1 Broadband Echosounder moduleCE

Página 31 - NMEA0183 Wiring

36 | Commission the System Commission the System 9. Turning on the system for the fi rst timeBefore starting the system for the first time, check the f

Página 32 - VIDEO IN

Commission the System | 37Commissioning ChecklistThe Zeus has a number of advanced features which can be configured through the settings menu.It is

Página 33 - Video Out

38 | Commission the System System settings menuTo access the system settings menu press LanguageLanguage used on menus and dialog boxesStep 1 Step 2 S

Página 34 - Connecting BroadBand™ Radar

Preface | 3Contents 2. Preface ... 1Introduction ...

Página 35 - Connecting HD Radar

Commission the System | 39Echosounder Setup Depth OffsetIs a value that can be entered to make the depth on the Echo page represent either depth bel

Página 36

40 | Commission the System Water Speed AveragingAverages water speed by measuring your speed at a selected interval of time. Water speed intervals ra

Página 37 - Commission the System 9

Commission the System | 41Radar Transmit, Standby or offPress Radar function button to display the radarMENU9WINPress Menu to bring up radar options

Página 38 - Commissioning Checklist

42 | Commission the System Data SetupData set up is required on initial start up of the system, or if any part of the SimNet or NMEA 2000 network has

Página 39 - 38

Commission the System | 43each of these categories a display can be set to receive data from sources as part of the Default group or receive the sou

Página 40 - Echosounder Setup

44 | Commission the System SimNet GroupsThe SimNet Group function is used to control parameter settings, either globally or in groups of units. It gr

Página 41 - Radar setup

Commission the System | 45DampingControls how quickly instruments respond to changes in values from sensors. Damping can be used for heading, wind,

Página 42 - Commission the System

46 | Commission the System Serial Port SetupConfigure the serial port to match the NMEA0183 device that it is connected to.Baud Rate (common for inpu

Página 43 - Data Setup

Commission the System | 47FuelIf the vessel has an NMEA2000 interface to its engines and fuel tanks. Zeus can display the following fuel consumption

Página 44 - Commission the System

48 | Commission the System DiagnosticsNMEA2000 DiagnosticsUser Database UDBThe diagnostic page shows the MAC address of the display, the status and ve

Página 45 - Nav Station

4 | Preface Ethernet ... 28Dual and Multi Station 29NMEA0183 Wirin

Página 46 - Device List

Commission the System | 49Check GPS SignalPress direct access key PAGES (3) If interfaced to H3000 Instruments via H-Link this feature is available

Página 47 - Serial Port Setup

50 | Commission the System Restore a System Backup FileRestoring data from a backup file will overwrite all existing data and settings with the data a

Página 48 - AIS Own Vessel

Commission the System | 51Ethernet Module Software VersionSoftware version : CA1637CExample below shows upgrading a ZG50 GPS Antenna. Steps 1 - 3 ar

Página 49 - Diagnostics

52 | Commission the System Screen CaptureIt is possible to capture a snap shot of the current screenStep 1 Step 2Enable screen captureCreate desired s

Página 50 - System Backup

Drawings | 53Drawings 10. Z8 Dimensions111.3 mm (4.38”)86.5 mm (3.40”)285.0 mm (11.22”)221.0 mm (8.70”)212.0 mm (8.35”)315.5 mm (12.40”)35 mm (1.38”

Página 51 - Software Upgrades

54 | Drawings Z12 Dimensions357.0 mm (14.01”)385 mm (15.16”)273.0 mm (10.75”)266.0 mm (10.47”)122.7 mm (4.83”)98 mm (3.85”)65 mm (2.55”)35 mm (1.38”)

Página 52 - Commission the System

Spare Parts | 55Spare Parts 11. Zeus Spare PartsPart Number Description000-10406-001 Bezel,Zeus,Z8000-10405-001 Bezel,Zeus,Z12000-10408-001 Sun cove

Página 53 - 52

56 | Spare Parts Compatible BSM-1 TransducersPart Number Description000-0136-02 Airmar P319, plastic, low profi le, thru hull 50/200 KHz, depth/temp,

Página 54 - Drawings 10

Spare Parts | 5724005894 SimNet termination plug44172278 SimNet termination In-Line joiner24005902 2 m (6.6 ft) SimNet power w/termination24005910 2

Página 55 - 35 mm (1.38”)

58 | Specifi cations Specifi cations 12. MechanicalBack Case Die cast aluminium Heat Sinking Direct heat transfer from processor to castingScreen Direct

Página 56 - Spare Parts 11

Preface | 5Drawings ... 53Z8 Dimensions ...

Página 57 - SimNet Accessories

Specifi cations | 59Display Specifi c Specifi cationsZ8 Z12Display size 8 “ Diagonal Display size 12.1” DiagonalDisplay resolution 800 x 600 Display re

Página 58 - Repeat Screens

60 | Specifi cations NMEA 2000 PGN ListNMEA 2000 PGN Receive59392 ISO Acknowledgement59904 ISO Request60928 ISO Address Claim60928 ISO Address Claim1

Página 59 - Specifi cations 12

Specifi cations | 61NMEA2000 PGN Transmit126208 ISO Command Group Function126992 System Time126996 Product Info127237 Heading/Track Control127250 Ve

Página 60 - Specifi cations

www.bandg.com*988-0186-01A*

Página 61 - NMEA 2000 PGN List

6 | Introduction Introduction 3. About this ManualThis manual is a reference guide for installing the B&G Z8 and Z12 Multi Function Display.The in

Página 62 - NMEA2000 PGN Transmit

Introduction | 7Check the PartsPackaged Parts List8“ Display unitPN location specifi cZ8 Bezel000-10406-00112 “ Display unitPN location specifi cZ12 B

Página 63 - *988-0186-01A*

8 | Overview Overview 4. ECHORADARCHART NAV INFO PAGESMENUPLOTGO TOMARKVESSELWININMOBABC DEF123JKLGHI MNO456TUVPQRSWXYZ7STBYAUTOPWR809OUT12 4679115810